ZX Series Horizontal Self-priming Centrifugal Pump 


Darui Electric recommends for you:

  ZX Type Pipeline Pumpis more effective as an emergency pump in industrial and agricultural production, rescue and disaster relief, such as drainage and firefighting.. ZX Type Self-priming Centrifugal Pumpis widely used in petroleum, chemical, metallurgy, machinery, chemical fiber, food, energy, transportation and other industrial sectors for urban water supply, and also for agricultural irrigation and sprinkler irrigation. It is suitable for conveying clean water or other liquids with viscosity less than 5°E, temperature below 80℃, and physical and chemical properties similar to clean water.

ZX series self-priming pumps are self-priming centrifugal pumps. They have the advantages of compact structure, convenient operation, balanced operation, easy maintenance, high efficiency, long service life, and strong self-priming ability. There is no need to install a bottom valve in the pipeline. Before work, only ensure that a certain amount of priming liquid is stored in the pump body. Therefore, the pipeline system is simplified and working conditions are improved.2. Product Uses:


Suitable for urban environmental protection, construction, fire protection, chemical industry, pharmaceutical, dyeing and printing, brewing, electric power, electroplating, papermaking, petroleum, mining, equipment cooling, oil tanker unloading, etc.

Suitable for clean water, seawater, water and chemical media liquids with acid and alkali, and general pasty slurries (medium viscosity ≤100 centipoise, solid content up to 30%).

When equipped with a rocking nozzle, water can be sprayed into the air and dispersed into fine droplets for spraying. It is a good tool for pesticides, nurseries, orchards, and tea gardens.

It can be used with any model and specification of filter press to deliver slurry to the filter press for pressure filtration as a matching pump.



 



3. Working Principle and Structure Description:



This pump adopts a pump body structure with axial liquid return. The pump body consists of a suction chamber, a liquid storage chamber, a volute chamber, a liquid return hole, and a gas-liquid separation chamber. After the pump starts normally, the impeller draws in the liquid stored in the suction chamber and the air in the suction pipeline together, and they are completely mixed in the impeller. Under the action of centrifugal force, the liquid carries gas to the outer edge of the volute chamber, forming a white foam belt of a certain thickness and a high-speed rotating liquid ring on the outer edge of the impeller. The gas-liquid mixture enters the gas-liquid separation chamber through the diffuser tube. At this time, due to the sudden decrease in flow rate, the lighter gas is separated from the mixed gas-liquid, and the gas continues to rise and discharge through the pump outlet. The degassed liquid returns to the liquid storage chamber and enters the impeller again through the return hole, mixing again with the gas sucked from the suction pipeline inside the impeller, and under the action of the high-speed rotating impeller, flows to the outer edge of the impeller again. As this process repeats, the air in the suction pipeline gradually decreases until all gas is exhausted, completing the self-priming process, and the pump then operates normally.



Some pump bearing housings are also equipped with a cooling chamber at the bottom. When the bearing temperature rises above 70℃ due to bearing heating, cooling liquid can be injected through any cooling liquid pipe joint at the cooling chamber for circulating cooling. The sealing mechanism inside the pump to prevent liquid leakage from the high-pressure zone to the low-pressure zone is the front and rear sealing rings. The front sealing ring is on the pump body, and the rear sealing ring is installed on the bearing housing. When the sealing rings wear to a certain extent after long-term operation and affect the pump efficiency and self-priming performance, they should be replaced.



Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.



WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us