Full Set Rental of Intelligent Dry Air Generator
Unique rapid regeneration technology for desiccant
With rapid regeneration technology, it can provide qualified dry air after 5-20 minutes of operation. Truly ready to use anytime without waiting.
Low dew point of product gas
The core indicator to measure a dry air generator is the dew point of the supplied gas. The lower the dew point, the drier the air. Low dew point dry air will absorb moisture inside the transformer to improve its insulation performance. The XL series dry air generator integrates compressed drying, refrigeration drying, and adsorption drying, and adopts a multi-stage filtration system. Due to the use of our company's independently developed "strong composite molecular adsorbent", no matter how much moisture is in the air, the dew point of the product gas will quickly drop below -70°C.
High-efficiency filtration system
Adopting "gradual density" filtration technology, with a filtration precision of 0.01μm and a solid particle retention rate of up to 99.99%. The primary filter has a filtration precision of μm, the secondary filter has a precision of 0.1μm, and the tertiary filter has a precision of 0.01μm.
Full set rental of intelligent dry air generator, completely abandoning adsorbent heating regeneration
The adsorbent adopts a heatless pressure-difference fully automatic regeneration method, completely eliminating the need for manual baking of the adsorbent.
Technical Parameters
|
Gas supply (m³/min) |
1 |
|
Working pressure (MPa) |
0.6-0.8 |
|
Dew point of product gas (°C) |
-40°C to -75��C |
|
Gas usage pressure (MPa) |
0-0.3 |
|
Dust particles (μm) |
≤0.01 |
|
Adsorbent regeneration |
Heatless automatic regeneration |
|
Adsorbent |
Strong composite molecular adsorbent |
|
Ambient temperature (°C) |
-20-40 |
|
Power (kW) |
18 |
|
Power supply |
380V/50Hz three-phase four-wire |
|
Equipment weight (kg) |
900 |
Instructions
1. Full set rental of intelligent dry air generator, connect to a three-phase four-wire power supply.
2. Open the ball valve in the pipeline to keep it unobstructed. Open the drain valve to release the water vapor inside, then close the drain valve.
3. Open the circuit breaker in the control box. If you hear an alarm sound from the air compressor, it means that any two of the three-phase wires of the air compressor need to be swapped. The air compressor starts, and the air compressor starts for a moment.
Turn on the cold dryer switch, and the adsorption dryer controller starts